Specifications:
- **Nominal Voltage:** 6V
- **Nominal Capacity:** 180Ah @ 20-hour rate F.V. (1.75V/cell)
- **Approx. Weight:** 28.8Kg (63.5lbs.)
- **Terminals:** B9 (Fitting M8 bolt & nut), I3 optional
- **Internal Resistance:** ≤2.5mΩ (Fully Charged)
- **Max. Discharge Current:** 800A (5 sec.)
- **Max. Charge Current:** 54A
- **Operating Temperature Range:**
- Charge: 0°C to 40°C (32°F to 104°F)
- Discharge: -20°C to 50°C (-4°F to 122°F)
- Storage: -20°C to 40°C (-4°F to 104°F)
### Compliance:
- IEC 60896-21/22
- JIS C 8704-2
- GB/T 19638.2
BP180-6-BB Battery6V180AH
### VRLA Rechargeable Battery
#### BP180-6
---
### Features:
- **Maintenance Free:** No topping up required.
- **Non-spillable:** No free electrolyte.
- **Low Self Discharge:** Less than 3% per month.
- **Suitable for Vertical & Horizontal installations.**
- **Integrated Flame Arrestor at each cell!**
- **Carry Handles:** Easy installation.
### Applications:
- UPS
- Telecom Systems
- Switch Boards
- Photovoltaic Systems
- Elevated Platforms
- Golf Carts
### Specifications:
- **Nominal Voltage:** 6V
- **Nominal Capacity:** 180Ah @ 20-hour rate F.V. (1.75V/cell)
- **Approx. Weight:** 28.8Kg (63.5lbs.)
- **Terminals:** B9 (Fitting M8 bolt & nut), I3 optional
- **Internal Resistance:** ≤2.5mΩ (Fully Charged)
- **Max. Discharge Current:** 800A (5 sec.)
- **Max. Charge Current:** 54A
- **Operating Temperature Range:**
- Charge: 0°C to 40°C (32°F to 104°F)
- Discharge: -20°C to 50°C (-4°F to 122°F)
- Storage: -20°C to 40°C (-4°F to 104°F)
### Compliance:
- IEC 60896-21/22
- JIS C 8704-2
- GB/T 19638.2
### Dimensions (mm/inch):
- **Length:** 260±2.0 (10.24±0.08)
- **Width:** 171±2.0 (6.73±0.08)
- **Container Height:** 220±2.0 (8.66±0.08)
- **Total Height:** 244±2.0 (9.61±0.08)
### Terminal Type:
- **Terminal B9**
- **Terminal I3**
- **M8x1.25**
### Terminal Hardware Initial Torque:
- B9, I3: 10.0Nm±5%
### Constant Power Discharge Characteristics at 25°C/77°F (Unit: W):
| Discharge Time | 15 Min | 30 Min | 1 Hr | 3 Hr | 5 Hr | 10 Hr | 20 Hr |
|----------------|--------|--------|-------|-------|-------|-------|-------|
| **15 Min** | 116.5 | 65.1 | 35.3 | 33.3 | 31.7 | 32.1 | - |
| **30 Min** | 180.9 | 101.1 | 49.6 | 46.6 | 44.2 | 45.6 | - |
| **1 Hr** | 267.6 | 183.6 | 102.6 | 95.6 | 89.0 | 91.0 | - |
| **3 Hr** | 376.8 | 270.0 | 184.6 | 170.0 | 157.2 | 159.5 | - |
| **5 Hr** | 468.6 | 326.4 | 216.4 | 197.0 | 182.5 | 184.6 | - |
| **10 Hr** | 578.7 | 399.1 | 264.0 | 238.0 | 218.0 | 213.5 | - |
### Constant Current Discharge Characteristics at 25°C/77°F (Unit: A):
| Discharge Time | 1 Hr | 3 Hr | 5 Hr | End Voltage |
|----------------|-------|-------|-------|-------------|
| **1 Hr** | 110.1 | 113.4 | 113.5 | 5.40V |
| **3 Hr** | 143.7 | 144.5 | 144.5 | 5.25V |
| **5 Hr** | 130.1 | 130.6 | 130.9 | 5.10V |
Contact: Albert Shu
Phone: 13775032303
Tel: 400-1177-032
Email: 13775032303@139.com
Add: Room 2-3208, Financial Street Rongyu, No. 780 Wanhangdu Road, Jing'an District, Shanghai, China